Leave Your Message

ChallengePore® PP Clarification filtration series

Constructed with multiple layers of polypropylene membranes of varying pore sizes,scientifically combined to provide high retention,high throughput,and excellent fouling capacity. 

    Superior Compatibility:
    ● Compatible with both Autoclave and Gamma irradiation;
    ● Highly compatible with a wide range of common solvents used in biopharmaceutical manufacturing.
    Pigment-Free Construction
    All plastic components, seals, and accessories are pigment-free, minimizing the risk of extractables and leachables (E&L) for a more hygienic process. Fully compliant with USP Class VI and ISO 10993 biocompatibility standards.
    100% Integrity Assurance
    Through rigorous process controls and stringent factory release testing, we ensure a 100% qualification rate for all outgoing products.
    Operating under ISO 9001 and compliant with GMP regulations; Meets stringent testing standards including:Bacterial Endotoxins: USP <85>,Biocompatibility: USP <87> & <88>,Extractables: USP <665>,Free from animal-derived components (TSE/BSE Free)
    Validated Excellence:
    Products are validated by world-leading agencies such as SGS and NF, ensuring every batch meets international validation standards.
    Challenge IM Capsule Filters are specifically designed for the biopharmaceutical industry. They are suitable for applications such as buffer filtration, intermediate product and drug substance filtration, as well as terminal filtration. This product has passed multiple tests conducted by the internationally recognized testing agency: SGS (SGS-CSTC Standards Technical Services Co., Ltd.).
    Partial List of Executed Standards
    ASTM F838: Standard Test Method for Determining Bacterial Retention of Membrane Filters for Liquids
    USP <665>:United States Pharmacopeia: Extractables and Leachables (E&L) Testing in Biopharmaceutical Production
    USP <87>: Biological Reactivity Tests, In Vitro.
    USP <88>: Biological Reactivity Tests, In Vivo (Class VI)
    [Typical Applications]
    ● Pre-filtration of cell culture media
    ● Clarification of fermentation broth or cell culture harvest
    ● Pre-filtration of serum and blood products
    ● Pre-filtration of colloids or viscous fluids
    Working Conditions
    Max. Operating Temp 80°C
    Max. Operating DP 0.55 MPa @ 25°C
    0.1 MPa @ 80°C
    Biological Safety
    Endotoxin: < 0.25 EU/mL
    Biocompatibility: Complies with USP <88> Class VI Biological Reactivity requirements for plastics

     [Filter Dimensions]

    Capsule Filters

    Cartridg

    01:0.04 m²

    05:0.2 m²

    02:0.08 m²

    10:0.4 m²

    04:0.15 m²

    20:0.8 m²

    05:0.15 m²

    30:1.2 m²

    10:0.4 m²

    40:1.6 m²

    20:0.8 m²

     
    [ Materials of Construction ]

    Filter Type

    Capsule Filter

    Cartridge Filter

    Filter Membrane

    Polypropylene(PP)

    Polypropylene(PP)

    Core/Cage/End Caps

    Polypropylene(PP)

    Polypropylene(PP)

    Capsule Housing

    Polypropylene(PP)

    —

    Cartridge O-ring

    —

    Silicone,EPDM, Viton, Encapsulated PTFE

    Vent O-ring

    Silicone

    —

    Micron Rating)

    0.2 / 0.5 / 0.65 / 1.0 / 3.0 / 5.0 / 10 / 20 / 30 μm

     

    [Sterilization Methods] Challenge Pore® PP Capsule Filters & Cartridges: Autoclave Sterilization up to 25 cycles.

    Superior Compatibility:
    ● Compatible with both Autoclave and Gamma irradiation;
    ● Highly compatible with a wide range of common solvents used in biopharmaceutical manufacturing.
    Pigment-Free Construction
    All plastic components, seals, and accessories are pigment-free, minimizing the risk of extractables and leachables (E&L) for a more hygienic process. Fully compliant with USP Class VI and ISO 10993 biocompatibility standards.
    100% Integrity Assurance
    Through rigorous process controls and stringent factory release testing, we ensure a 100% qualification rate for all outgoing products.
    Operating under ISO 9001 and compliant with GMP regulations; Meets stringent testing standards including:Bacterial Endotoxins: USP <85>,Biocompatibility: USP <87> & <88>,Extractables: USP <665>,Free from animal-derived components (TSE/BSE Free)
    Validated Excellence:
    Products are validated by world-leading agencies such as SGS and NF, ensuring every batch meets international validation standards.
    Challenge IM Capsule Filters are specifically designed for the biopharmaceutical industry. They are suitable for applications such as buffer filtration, intermediate product and drug substance filtration, as well as terminal filtration. This product has passed multiple tests conducted by the internationally recognized testing agency: SGS (SGS-CSTC Standards Technical Services Co., Ltd.).
    Partial List of Executed Standards
    ASTM F838: Standard Test Method for Determining Bacterial Retention of Membrane Filters for Liquids
    USP <665>:United States Pharmacopeia: Extractables and Leachables (E&L) Testing in Biopharmaceutical Production
    USP <87>: Biological Reactivity Tests, In Vitro.
    USP <88>: Biological Reactivity Tests, In Vivo (Class VI)
    [Typical Applications]
    ● Pre-filtration of cell culture media
    ● Clarification of fermentation broth or cell culture harvest
    ● Pre-filtration of serum and blood products
    ● Pre-filtration of colloids or viscous fluids
    Working Conditions
    Max. Operating Temp 80°C
    Max. Operating DP 0.55 MPa @ 25°C
    0.1 MPa @ 80°C
    Biological Safety
    Endotoxin: < 0.25 EU/mL
    Biocompatibility: Complies with USP <88> Class VI Biological Reactivity requirements for plastics

     [Filter Dimensions]

    Capsule Filters

    Cartridg

    01:0.04 m²

    05:0.2 m²

    02:0.08 m²

    10:0.4 m²

    04:0.15 m²

    20:0.8 m²

    05:0.15 m²

    30:1.2 m²

    10:0.4 m²

    40:1.6 m²

    20:0.8 m²

     
    [ Materials of Construction ]

    Filter Type

    Capsule Filter

    Cartridge Filter

    Filter Membrane

    Polypropylene(PP)

    Polypropylene(PP)

    Core/Cage/End Caps

    Polypropylene(PP)

    Polypropylene(PP)

    Capsule Housing

    Polypropylene(PP)

    —

    Cartridge O-ring

    —

    Silicone,EPDM, Viton, Encapsulated PTFE

    Vent O-ring

    Silicone

    —

    Micron Rating)

    0.2 / 0.5 / 0.65 / 1.0 / 3.0 / 5.0 / 10 / 20 / 30 μm

     

    [Sterilization Methods] Challenge Pore® PP Capsule Filters & Cartridges: Autoclave Sterilization up to 25 cycles.

    Ordering information

    ChallengePore® PP clarification filtration series

    Capsule filters

    c1
    Filter type Membrane material Pore size(μm) Length(") Configuration Inlet Outlet O-ring Sterilization

    K-

    Capsule filters

    E5-PP

    081=0.1

    082=0.2

    084=0.45

    086=0.65

    001=1.0

    003=3.0

    005=5.0

    010=10

    020=20

    030=30

    01=1

    02=2

    04=4


    05=5

    10=10

    20=20

    L=In-line

    (Top-in/Bottom-out)

    D=1/4"HBB

    E=3/8"HBB

    F=1/2"HB

    G=1/2"TC

    H=1-1.5"TC

    J=1-(1/2"HB


    H=1.5"TC

    F=1/2"HB

    D=1/4"HBB

    E=3/8"HBB

    F=1/2"HB

    G=1/2"TC

    H=1-1.5"TC

    J=1-(1/2"HB


    H=1.5"TC

    F=1/2"HB

    S=Silicone

    E=EPDM

    V=FKM

    Default:

    Autoclavable,

    Non-sterile

    Filter cartridge

    c2
    Filter type Membrane material Pore size(μm) Length(") Adapter End cap O-ring
    C-Filter cartridge E5-PP

    081=0.1

    082=0.2

    084=0.45

    086=0.65

    001=1.0

    003=3.0

    005=5.0

    010=10

    020=20

    030=30

    05=5

    10=10

    20=20

    30=30

    40=40

    A=226

    B=222

    P=Flat cap

    R=Fin

    S=Silicone

    E=EPDM

    V=Viton